Evaporative air cooler maintenance and cleaning procedures:

1, Before maintenance: Please check if there are any obstructions around the unit and at the air intake, and clean up any fallen leaves or dust around.

2,Unit periodic maintenance: After the unit has been running for 6 to 8 months, if the cooling pad, filter blocks or chassis become too dirty, they should be cleaned promptly to prevent machine malfunctions.

3, unit maintenance: (long time not use, remember to drain water and cut off the power!) In order to prevent freezing damage to the body and the breeding of mosquitoes, when it is stopped for a long time, the tap water should be turned off, then press the "Drain" button to drain the water and cut off the power supply.

4, the internal cleaning of the unit: if the unit runs for a long time, in order to ensure the refrigeration effect, it is necessary to clean the machine once every two quarters. (This is determined based on the local environment and water quality.)

 

Maintenance and cleaning steps are as follows:

(1) Remove the cooling pad

    1. Remove the cooling pad buckle first.

    2. Hold the side panel of the upper part of the cooling pad in hand, pull the cooling pad gently outward and then lift it slightly upward to remove the cooling pad.

    3, wash the cooling pad from the inside out with clean water (note: do not use acid or alkaline cleaning detergent to clean the laundry cooling pad)

    4, filter: It is recommended that the filter can be removed and cleaned  once every 1-2 seasons (based on the local environment).

(2) Cleaning of cooling pad distributor.

    1, if the hole on the cooling pad distributor is blocked, it can be pierced with a wire.

    2, clean the stains on the cooling pad distributor with clean water.

(3), chassis and accessories cleaning.

    1. Clean the chassis: clean the chassis with a soft cloth or brush.

    2, clean the wind leaf: wipe the wind leaf with a soft cloth. Be careful not to drop dust from the blades into the duct.

    3. Clean the water level sensor: clean the dirt on the water level with a wet cloth.

    4, clean the pump: use a brush to clean the water pump and the dirt on the filter net.

    5, clean the drainage valve: pay attention to the dirt at the bottom of the drainage valve.

Note: When cleaning the unit, it must be shut down and turn off the power supply, otherwise there will be a risk of electric shock or other injuries to the human body. When working at height, you must wear a safety belt and do a good job of safety.

Tips: In order to ensure the safety of air conditioners in winter, turn off the water valve, turn off the power supply, clean the water storage pan thoroughly, and discharge clean, and then shut down and cut off the power supply.

 

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Copyright © 2025 Aolan (Fujian) Industry Co., Ltd All Rights Reserved. Network Supported

Blog Sitemap Xml Privacy Policy

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

Home

products

whatsApp

contact

Leave A Message
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit